Liquid Cooling Unit LCU DX, redundant

Liquid Cooling Unit LCU DX, redundant

Coolant-based enclosure cooling in redundant configuration for TS IT or Micro Data Center without heating up the installation room. With two output categories – 3 kW and 6.5 kW – an ideal cooling solution for smaller IT applications.

3311493

$100.00
VersionLCU DX 6.5 kW redundant
BenefitsMaximum energy efficiency due to EC fan technology and IT-based control
Control of the server inlet temperature
Absorbed thermal energy is emitted directly into the ambient air at the location of the (inverter controlled) external unit without heating up the installation room
Space-saving solution by installing the redundant internal unit in the TS IT server enclosure or the Micro Data Center
The inverter-controlled compressor matches the cooling output to the current level of heat loss in the enclosure
ApplicationsRedundant cooling unit for TS IT server enclosures and Micro Data Center
Useful cooling output L22 L356.5 kW
NoteThe specified operating temperature applies to the external unit
Supply includes2 external units (inverter controlled)
482.6 mm (19") mounting bracket cover with control and display elements
Condensate hose
Internal unit (condenser)
with depth1000 mm (39 ")
with width800 mm (31 ")
Height1800 mm (71 ")
NoteA separate power supply is required for each external unit
If the cooling output falls below its minimum value fluctuations in the air intake temperature may result
The electrical connection is made to the external unit; the internal unit is supplied by the external unit
Rated operating voltage230V 1~ 50Hz
Cooling mediumR410a
Type of connection (electrical)Connection clamp
Duty cycle100 %
Packaging unit1 pc(s).
Weight/packaging unit184 kg (405.7 lb.)
EAN4028177709362
Customs tariff number84158200
ETIM 6.0EC000855
VariantRack cooling
ETIM 5.0EC000855
eCl@ss 8.0/8.127180704
Total cooling output6.5 kW
eCl@ss 7.0/7.127180704
eCl@ss 6.0/6.127180704
eCl@ss 5.1/5.1.427180704
Product description (long)SK LCU DX split cooling unit 6 5 kW Refrigerant-based cooling of TS IT racks and Micro Data Center 2 x external units with inverter regulated compressors 1 x internal unit redundant
Device modulates without interruption in the cooling output range between3kW - 6 5kW
ColorExternal unit: white
Internal unit: RAL 7035
Function principleThe device supports "front to back" air routing typical of IT applications and regulates the server inlet temperature to the set value
Within the internal unit the redundant versions each have two cooling circuits and two controllers plus two inverter-controlled external units. The fault and operating hours switchover mechanism ensures regular switching between the external units and a
Protection category IP to IEC 60 529External unit IP X4
Internal unit IP 20
Refrigerant cooling mediumR410a
At 230 V/50 Hz15.9 A
More Info
Certificates
EAC
Declarations
Declaration of conformity
Documentation
Instructions
Pos. Name Shop Valid From Model No.
5 Axial fan
- 3398429
6 Grille
- 3398451
10 Radial fan
- 3398442
20 Expansion valve
- 3398443
40 Controller
- 3398441
45 Controller
- 3398436
50 Display
- 3398440
55 Controller
- 3398438
70 Temperature sensor
- 3398437